 SIP43101
New Product
Vishay Siliconix
Dual Output Power Switch with Inverting Input
FEATURES
D D D D D D Two Output Power Switches Total Output Drive -- 200 mA Continuous 9-V to 35-V Supply Voltage Range Low Side or High Side Switch Configuration User Programmable Phasing of Output Switches Internal Output Over Voltage Clamp For Driving Inductive Loads D Current Limit Protection D Thermal Shutdown Protection D UVLO With User Programmable Time Delay
APPLICATIONS
D Optical Detectors for Factory Automation
DESCRIPTION
SIP43101 is a dual power switch IC which contains all control and power switching circuitry required to drive resistive and inductive loads in industrial applications. The output switches are NPN power transistors which can be configured as either high-side or low-side switches. These switches can operate from voltages as high as 35 V and have a continuous output current rating of 200 mA, combined or individually. Internal zener diodes are provided to clamp the power switch voltages to safe levels when driving inductive loads. The IN1 pin is a non-inverting input which controls the output of switch 1. A 2-input Exclusive OR gate input controls switch 2, allowing switch 2 to be controlled by either an inverting or non-inverting control signal. SIP43101 contains under voltage lockout, UVLO, a user definable turn on delay, current limit, short circuit protection, and thermal shutdown. SIP43101 is available in 16-pin TSSOP and PowerPAKr MLP-44 packages for operation over the temperature range of -40 to 85 C.
TYPICAL APPLICATION CIRCUIT
+10 to 30 V 5V 100 nF Load Load
SIP43101
1 kW 10 kW VCC FAULT INPUT IN1 IN2A IN2B CDEL 10 kW 100 nF GND C1 E1 C2 E2
GND
Both Switches Configured as Low-Side, Switch 2 Inverted With Respect to Switch 1
Document Number: 72640 S-32451, Rev. A--01-Dec-03 www.vishay.com
1
SIP43101
Vishay Siliconix
ABSOLUTE MAXIMUM RATINGS
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V C1, E1, C2, E2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V C1-E1, C2-E2 (clamped by internal circuitry) . . . . . . . . . . . . . . . . . . . . . . 52 V Output Current Continuous for one Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mA Peak for one Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 A Currents are positive into, negative out of the specificed terminal. FAULT Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mA FAULT Output Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.5 V IN1, IN2A, IN2B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.5 V Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to 150_C Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55 to 125_C
New Product
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING RANGE
VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 to 32 V Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . -40 to 85_C
SPECIFICATIONS
Test Conditions Unless Specified Parameter Power Supply
Supply Voltage Supply Current VCC ICC -40 to 85_C, Both Inputs Enabled 9 6 35 9 V mA
Limits Mina Typb Maxa Unit
Symbol
VCC = 25 V,IN1, IN2 = 0 V, IN1, IN2, INV2 = 5 V CDEL = 10 nF, TA = TJ
Logic Inputs (IN1, IN2A, IN2B)
Digital Input High Level Digital Input Low Level Input Bias Current, Low Level Input Bias Current, High Level VIH VIL IIL IIH IN1, IN2A, IN2B = 0 V IN1, IN2A, IN2B = 5 V -0.40 0.02 3.5 9 1.5 V mA
Switches 1&2 - High Side Configuration
Rise Time (Off to On) Rise Tiem (On to Off) Saturation Voltage Current Limit Leakage Current Voltabe Clamp tr tf VSATHS ILIMHS ILHS VCLHS RLOAD = 250 W to GND, C1 , C2 = 25 V GND RLOAD = 125 W to GND TA = 25 _C TA = -40 _C 1.1 5 52 300 300 1.3 1.5 ns V A mA V
RLOAD = 0.25 W to GND, TA = 25 _C E1, E2 = GND, C1 , C2 = 25 V,IN1, IN2A, IN2B = 0 V Measure (VC1 - VE1) or (VC2 - VE2)
Switches 1&2 - Low Side Configuration
Rise Time (On to Off) Rise Tiem (Off to On) Saturation Voltage Current Limit Leakage Current Voltabe Clamp tr tf VSATLS ILIMLS ILLS VCLLS RLOAD = 250 W to VCC, LOAD = 25 V to C1 , C2 RLOAD = 125 W to VCC TA = 25 _C TA = -40 _C 1.1 5 52 400 350 1.3 1.5 ns V A mA V
RLOAD = 0.25 W to VCC, TA = 25 _C E1, E2 = GND, C1 , C2 = 25 V,IN1, IN2A, IN2B = 0 V Measure (VC1 - VE1) or (VC2 - VE2)
Turn-On Delay
CDEL Maximum Voltage CDEL Threshold ICDEL www.vishay.com VDEL VDELTH ICDEL 4.7 4 2.5 V mA
2
Document Number: 72640 S-32451, Rev. A--01-Dec-03
SIP43101
New Product
SPECIFICATIONS
Test Conditions Unless Specified Parameter FAULT Output
VCESAT Conducting State (On) VSDON 10 mA Load on FAULT 0.4 V
Vishay Siliconix
Limits Mina Typb Maxa Unit
Symbol
VCC = 25 V,IN1, IN2 = 0 V, IN1, IN2, INV2 = 5 V CDEL = 10 nF, TA = TJ
Operating Frequency
Switching Frequency fSW 25 kHz
Under Voltage Lockout
UVLO Threshold UVLO Hysteresis VUVLO VHYS 7.5 0.4 8 0.5 8.5 0.6 V
Thermal Shutdown
Thermal Shutdown Threshold Hysteresis T THYS 160 20 _C
Notes a. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum (-40_ to 85_C). b. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing and are measured at VCC = 12 V unless otherwise noted.
PIN CONFIGURATION
TSSOP-16
VCC FAULT CDEL NC GND IN2B IN2A IN1 1 2 3 4 5 6 7 8 Top View 16 15 14 13 12 11 10 9 C2 NC E2 NC NC E1 NC C1
TSSOP-16 ORDERING INFORMATION
Part Number
SIP43101DQ-T1
Temperature Range
-40 to 85_C
Marking
43101
PowerPAK MLP-44
C2 13 NC 14 VCC FAULT 15 16
E2 NC NC E1
12 11 10 9
1 2 3 4
CDEL GND NC IN2B
PowerPAK MLP-44 ORDERING INFORMATION
Part Number
SIP43101DLP-T1
Temperature Range
-40 to 85_C
Marking
43101
8 C1
7 NC
6 IN1
5 IN2A
Bottom View Document Number: 72640 S-32451, Rev. A--01-Dec-03 www.vishay.com
3
SIP43101
Vishay Siliconix
PIN DESCRIPTION
Pin Number TSSOP-16
1 2 3 4, 10, 12, 13, 15 5 6 7 8 9 11 14 16
New Product
MLP44-16
15 16 1 3, 7, 10, 11, 14 2 4 5 6 8 9 12 13
Name
VCC FAULT CDEL NC GND IN2B IN2A IN1 C1 E1 E2 C2 Positive Supply Voltage
Function
Open collector output that is switched low on in the event of Short Circuit or Thermal Shut Down. Connection for the external capacitor controlling the turn on delay. No connection Ground Pin. Input to the Exclusive OR controlling power switch 2. Input to the Exclusive OR controlling power switch 2. Input controlling power switch 1. Collector of power switch 1. Emitter of power switch 1. Emitter of power switch 2. Collector of power switch 2.
DETAILED PIN DESCRIPTION
CDEL A capacitor connected to this pin is used to set the duration the turn on delay. The delay starts after the UVLO threshold has been reached. E1 This pin is the emitter of Switch 1. This pin is connected to the load in the High-Side Switch configuration, and is connected to Ground in the Low-Side configuration. E2 IN1 This pin controls the state of the output NPN switch 1. A Logic 0 holds the switch off while a Logic 1 turns the switch on. This pin is the emitter of switch 2. This pin is connected to the load in the High-Side switch configuration, and is connected to Ground in the Low-Side configuration. C1 IN2A, IN2B These pins are the inputs to the Exclusive OR gate that controls the state of the output NPN switch 2. This allows the use of either a non-inverting or an inverted signal to control the switch. Refer to the truth table for the logic function description. This pin is the collector of switch 1. This pin is connected to the VCC in the High-Side switch configuration, and is connected to the load in the Low-Side configuration. C2 This pin is the collector of switch 2. This pin is connected to the VCC in the High-Side switch configuration, and is connected to the load in the Low-Side configuration. FAULT This pin is an open collector output that is pulled to Ground in the event of a short circuit, an overcurrent, or a thermal shut down
Document Number: 72640 S-32451, Rev. A--01-Dec-03
IN2A
Low Low High High www.vishay.com
IN2B
Low High Low High
SWITCH 2
Off On On Off
4
SIP43101
New Product
FUNCTIONAL BLOCK DIAGRAM
Vishay Siliconix
VCC
Reference
C2
CDEL
UVLO
E2
Reset
FAULT
Control Logic
C1
Short Citcuit Thermal Shut Down
E1
IN2B IN2A IN1 GND
DETAILED OPERATION
Turn On Delay The turn on delay prohibits the output switches from being turned on for a period of time after VCC has passed through 8 V and the undervoltage condition no longer exists. The UVLO function keeps the external CDEL capacitor discharged until VCC is greater than 8 V. Subsequently, an internal 2.5-mA current source charges the capacitor from GND to 4.7 V. A comparator detects when the voltage on CDEL passes through 4 V and enables the output switches. The delay time is a function of the capacitor value and is defined as 1.6 ms/nF. An external switch can be connected across the capacitor to disable the output switches and reset the time delay. Short Circuit and Overcurrent indication When an overcurrent or short circuit condition occurs on either switch, the SIP43101 enters a hiccup current limiting mode. In this mode, the capacitor on CDEL is discharged down to 3 V, thus turning off the output switches, and then is charged up to 4 V by a 2.5-mA internal current source, thus turning the switches on again. If the overcurrent or short circuit condition remains this cycle will continue. The switches are enabled at a very low duty cycle, minimizing the power dissipation and protecting the switches from damage. The FAULT output will switch to GND, indicating that an overload condition or short circuit condition exists.
Document Number: 72640 S-32451, Rev. A--01-Dec-03
www.vishay.com
5


▲Up To Search▲   

 
Price & Availability of SIP43101

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X